<LOGO>
FM Transmitter Measurement Report
Created: 2024-10-20 13-56-46
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.30 MHz 5/5, 73 dBuV NOSTALGI
Pilot RDS Phase Difference
6.1 kHz 3.1 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
13 kHz 66 kHz 12283 0,0000
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
4,5 dBr 6,20 dBr 6,7 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"NOSTALGI" 6411 10 (Pop M) 1 0 1 7 --:--
RT
"Elamasi musiikkia. "
AF EON
92.7, 94.3, 99.5, 100.5 MHz -
FM Scope Max at: 66 kHz MIN: 13 kHz % above 76 kHz: 0,0000 Acquired: 2024/10/20 13.55.42 Total samples: 12283 Equivalent time: 0:10:14 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000 1500
FM Scope MAX: 6,7 dBr MIN: 4,5 dBr AVE: 6,20 dBr % above 12,2 dBr: 0,0 Last value: 6,7 dBr (2024/10/20 13.55.42) 13.42 13.44 13.46 13.48 13.50 13.52 13.54 0 50 100 Dev. MAX [kHz] 0 2 4 6 Pm [dBr]